What’s the C-menu? #
The C-menu is used to manage the Easybaby Milk Maker’s settings. For explanations of the different codes, see below.
C1
Here you can adjust the water. The default is 100. After calibration, enter the number you weighed on the scale during calibration. You can adjust this number by pressing the plus or minus button.
C2
Mixing ratio of powder and water. This is where you enter how much 1 scoop of powder weighs. You can usually find this information in the ingredients section of your milk powder packaging. Can’t find it? Weigh 10 scoops and enter this number here.
Per 30 ml of water, 1x the number of powder you entered is added. For example: would you like a bottle of 150 ml? Then 5x the number of powder you entered is added, e.g. 5 x 4.5 grams = 22.5 grams.
C3
Here you can adjust the powder. By default it is set to 15. After calibration, enter the number you weighed on the scale during calibration. You adjust this number by pressing the plus or minus button.
C4
C4 indicates the sensitivity of the bottle detection sensor. By default it is set to 180. The lower the number, the more sensitive the sensor. You can turn the sensor off by pressing and holding the menu button, the minus button and the start button at the same time until you hear a long beep. Pressing the same buttons also turns the sensor back on.
C5
You may ignore this one.
C6
Stands for Wi-Fi. 00 is Wi-Fi off and 01 is Wi-Fi on. The Milk Maker only works on 2.4 GHz. If you have the Wi-Fi set to 5 GHz, it needs to be reset. The app can only be connected to 1 (one) smartphone.
C7
Stands for the mixing bowl sensor. 00 is sensor off / 01 is sensor on.
If you have the sensor off, you cannot enter the C-menu. To get back into the menu, remove the mixing funnel and hold the plus and minus button until you see the temperature appear. When it is visible, hold the menu button until you see C1. You can get to C7 by pressing the menu button several times. Set it back to 01.